Charging Inlet Unlocker verification
Charging Inlet Unlocker verification
Overview
Automatic functional test of charging inlet service unlock system.
Adapter integrated in standard test table to pull from fhr unlock device with controlled force and distance.
Features
The typical pullback force, to pull the cable back to base position of the Service Unlock after a manual unlock of the actuator is => 5N/13,5V
Unlock force to manually unlock a locked actuator with service unlock=>50N
The cable retention force that actuator service can resist in end position=>120N
The pull distance of the service unlock from locked to unlocked position=>24.5mm ; +/-1.5mm
Saving force and distance into test report;
The clip is the reference point